Identification of leachate migration in an open-air dump by means of vertical electrical soundings

Authors

  • María del Sagrario Quiroz-Castillo Tecnológico Nacional de México - Instituto Tecnológico de Ciudad Madero
  • Diana Guadalupe López-Torres Tecnológico Nacional de México - Instituto Tecnológico de Ciudad Madero
  • Reinaldo David Martínez-Orozco Tecnológico Nacional de México - Instituto Tecnológico de Ciudad Madero
  • Óscar Alberto Izaguirre-Ávila Tecnológico Nacional de México - Instituto Tecnológico de Ciudad Madero

DOI:

https://doi.org/10.63728/riisds.v8i1.158

Keywords:

leachate, migration, site resistivity, electrical resistivity tomography, contamination

Abstract

In this work, the electrical resistivity method was used to identify possible areas of contamination due to an open-air municipal landfill, located in Ciudad Madero, Tamaulipas, Mexico. The study was carried out with the purpose of determining the presence and zone of influence of the leachate generated by landfill towards the surroundings of their location point. Like this, establish the direction of the leachate flow, according to the data of the geography of the study area, towards surrounding areas. such as lagoons and/or groundwater bodies. Results of 2D inversion at carried put profiles showed zones of low resistivity that indicate the influence of the leachate plume, with preferential migration towards groundwater derived from the stratigraphy that favors its runoff. The VES results showed a localized water table depth less than 10 m deep, with the leachate plume flowing in a northeasterly direction. These results show the importance and potential of electrical resistivity methods in the identification of leachate migration based on vertical electrical soundings, as well as, the choice of suitable land to act as dumps, according to its stratigraphy.

References

Abiriga, Daniel.; Vestgarden, Live S.; Klempe, Harald. (2020) Groundwater contamination from a municipal landfill: Effect of age, landfill closure, and season on groundwater chemistry. Science of the Total Environment 737, 140307.

Busquets, E., & Casas, A. (1995). Caracterización de vertederos y detección de penachos contaminantes mediante la utilización de métodos geofísicos. Física de la tierra, 7.

Christensen, T.H.; Kjeldsen, P.; Bjerg, P.L.; Jensen, D.L; Christensen, J.B.; Baun, A.; Albrechtsen, H-J.; Heron, G. (2001) Biogeochemistry of landfill leachate plumes. Applied Geochemistry, Vol 16, (7–8), 659-718.

Hasan, M., Shang, Y., Meng, H. et al. (2021) Application of electrical resistivity tomography (ERT) for rock mass quality evaluation. Sci Rep 11, 23683. DOI: 10.1038/s41598-021-03217-8.

Loke, M. H. & Barker, R. D. (1996) Practical techniques for 3D resistivity surveys and data inversion. Geophys. Prospect. 44(3), 499–523.

Mainoo, Patrick A.; Manu, E., Yidana, Sandow M.; Agyekuma, William A.; Stigterd, Tibor.; Duaha, Anthony A.; Prekoc, Kwasi. (2019) Application of 2D-Electrical resistivity tomography in delineating groundwater potential zones: Case study from the voltaian super group of Ghana. Journal of African Earth Sciences 160, 103618.

Ojo, Akintayo O.; Olurin, Oluwaseun T.; Ganiyu, Saheed A.; Badmus, Biodun S.; Idowu, Olufemi A. (2022) Electrical Imaging Characterization of a Dumpsite on an Abandoned Quarry Site in Abeokuta, South West, Nigeria. Scientific African 17, e01330.

Okpoli, Cyril Chibueze. (2013) Application of 2D electrical resistivity tomography in landfill site: A case study of Iku, Ikare Akoko, southwestern Nigeria, Journal of Geological Research, Article ID 895160, 8 pp, DOI: 10.1155/2013/895160.

Omolayo, Dare.; Tope, Fatoba Julius. (2014) 2D electrical imaging surveys for leachate plume migration at an old dump site in Ibadan south western Nigeria: A case study. International Journal of Geophysics Article ID 879530, 6 pp. DOI: 10.1155/2014/879530.

Ramakrishnan, A., Blaney, L., Kao, J. et al. (2015) Emerging contaminants in landfill leachate and their sustainable management. Environ Earth Sci 73, 1357–1368. DOI: 10.1007/s12665-014-3489-x.

Renou, S.; Givaudan, J.G.; Poulain, S.; Dirassouyan, F.; Moulin, P. (2008) Landfill leachate treatment: Review and opportunity. Journal of Hazardous Materials 150, 468–493.

Reyes-López, J.A.; Ramírez-Hernández, J.; Lázaro-Mancilla, O.; Carreón-Diazconti, C.; Martín-Loeches Garrido, M. (2008) Assessment of groundwater contamination by landfill leachate: A case in México. Waste Management 28, S33–S39.

Shi, Lei.; Chen, Huixin.; Meng, Huilin.; Cheng, Rong.; Dai, Jinguo.; Zheng, Xiang.; Zhang, Zhenxing. (2021) How environmental policy impacts technology adoption: A case of landfill leachate. Journal of Cleaner Production 310, 127484.

Ugbor, C.C.; Ikwuagwu, I.E.; Ogboke, O.J. (2021) 2D inversion of electrical resistivity investigation of contaminant plume around a dumpsite near Onitsha expressway in southeastern Nigeria. Sci Rep 11, 11854, DOI: 10.1038/s41598-021-91019-3.

Zhan, Lt., Xu, H., Jiang, Xm. et al. (2019) Use of electrical resistivity tomography for detecting the distribution of leachate and gas in a large-scale MSW landfill cell. Environ Sci Pollut Res 26, 20325–20343. DOI: 10.1007/s11356-019-05308-6.

Published

2022-12-16

How to Cite

Quiroz-Castillo, M. del S., López-Torres, D. G., Martínez-Orozco, R. D., & Izaguirre-Ávila, Óscar A. (2022). Identification of leachate migration in an open-air dump by means of vertical electrical soundings. Revista Interdisciplinaria De Ingeniería Sustentable Y Desarrollo Social, 8(1), 1–16. https://doi.org/10.63728/riisds.v8i1.158